← Back to search

MCC §14.05.030

Water main sizes

Read the official text at library.municode.com ↗

This section sets the minimum sizes for water mains in new subdivisions, based on the number of units and the zoning district. It also requires valves and similar equipment as the director decides. Fire flow standards guide the design.

developershomeowners

The ordinance, as written (Maui County) — Water mains and appurtenances

A copy, taken August 21, 2026. The version published by Maui County is the one that governs, and it may have changed since. Check it before relying on anything here.

A. Water main sizes shall be designed to deliver water quantities and pressure that meet department and the department of fire and public safety standards, for both domestic and irrigation uses under peak consumption conditions, as well as for fire protection. B. Size of Water Mains. 1. Urban and rural zoned districts. The standards of the "Insurance Service Office's Guide for Determination of Required Fire Flows" in effect at the time of a subdivision application shall be used as a guide in designing mains for fire flows. The minimum size main from the point of adequacy to, along, and within a subdivision shall be as follows: Minimum Size of Water Main 2 unit subdivision 6″ limited to 600′ run 8″ if run is over 600′ 3 to 12 unit subdivision 6″ limited to 600′ run 8″ if run is over 600′ 13 to 24 unit subdivision 6″ limited to 600′ run 8″ if run is over 600′ 25 and over unit subdivision 8″ or larger as determined by design for domestic and fire protection requirements.   All subdivisions shall provide six-inch water pipe or larger in residential district and eight-inch water pipe or larger in business, industrial, hotel, and apartment districts. A six-inch main shall be used only where it completes an adequate gridiron and in no case in blocks more than six hundred feet in length. 2. Agricultural zoned districts. Minimum Size of Water Main 2 unit subdivision 6″ limited to 1,200′ run; over 1,200′ size to be as determined by design for domestic and agricultural requirements. 3 to 6 unit subdivision 6″ limited to 1,200′ run; Over 1,200′ size to be as determined by design for domestic and agricultural requirements. 7 to 24 unit subdivision 6″ limited to 1,200′ run; Over 1,200′ size to be as determined by design for domestic and agricultural requirements. 25 and over unit subdivision 8″ or larger as determined by design for domestic and agricultural requirements.   C. Valves, pressure reducing units, etc., of such sizes, types and classes shall be installed as designated and required by the director. (Ord. No. 3730, § 1, 2010)
Read the official text at library.municode.com ↗as published Nov 21, 2025our copy taken Aug 21, 2026

Published by the County of Maui through Municode.

LawTrove is not legal advice. The summary above is a computer-generated restatement — the authoritative text is the official version linked above.