Fire flow requirements for one- and two-family homes

Read the official text at library.municode.com ↗

This rule sets the minimum water flow firefighters need for one- and two-family homes and their accessory buildings. It also allows sprinkler systems as an alternative when there is no approved water supply, and lists exceptions for greenhouses, agricultural lots, and small buildings.

buyerscontractorshomeownerslandowners

The ordinance, as written (Maui County) — Subsection 18.4.5.1.1 amended

A copy, taken August 21, 2026. The version published by Maui County is the one that governs, and it may have changed since. Check it before relying on anything here.

Section 18.4 of the NFPA 1, as amended by the State Fire Code, is amended by amending subsection 18.4.5.1.1 to read as follows: 18.4.5.1.1 The minimum fire flow and flow duration requirements for one- and two-family dwellings and related accessory buildings having a fire flow area that does not exceed 5000 square feet must be 1000 gpm (3785L/min) for one hour. If the subject parcel does not have an approved water supply for fire protection, the proposed structure may be protected by an approved automatic sprinkler system per NFPA 13 or NFPA 13D limited to not more than two one- and two-family dwellings. EXCEPTION: 1. Greenhouses. 2. Agriculture zoned lots having fire flow of 500 gpm for two hours. 3. One- or two-family dwellings or accessory buildings having a total area not exceeding 1,000 square feet fire flow may be modified. ( Ord. No. 5754 , § 3, 2024)
Read the official text at library.municode.com ↗as published Nov 21, 2025our copy taken Aug 21, 2026

Published by the County of Maui through Municode.

LawTrove is not legal advice. The summary above is a computer-generated restatement — the authoritative text is the official version linked above.